Download free quick sheet for uniden bcd436hp






















You can assign number tags to channels even if the Favorites List does not have a number tag but, without a Favorites List number tag, you can only navigate to these channels while holding or scanning in that Favorites List.

See also Using Number Tags. For each alert in the scanner, you can select from 9 different tone patterns, 15 volume settings, and for the LED Alert Light, set 7 colors, and 3 flash patterns. Worksheets I have put together complete pdf worksheets ready to print to help you plan your Systems, Close Call, and Fire Tone-Out, etc. Even if you don't fill them out, they are a good check list for programming. You should assign a Quick Key to every Favorites List to quickly enable or disable the list.

Review FL Avoids. Set FL Quick Key. Stop All Avoiding. Set FL Number Tag. Add Current dB Channels. Set FL Startup Key. Understanding Location Control Information. You can only use a FL QK once. The default setting is. Scroll to the QK number or. Note: Pressing the first number of a 2-digit QK will get you closer, 1 for 10, 2 for 20, etc. The default setting is no number tag blank. Enter the number tag Press.

The default settings are all keys Off. Press Menu to save. See also Understanding Location Control. Understanding Location Control. Location Control allows you to enable or disable channels scanned in a Favorites List based on your location. Your Departments and Sites have locations and ranges programmed.

The scanner then compares your location data with Site and Department data to determine which channels to scan. If you are traveling long distances hooking up a GPS device would be a better way to go. See also Review Scan Avoids. See also Clear All Scan Avoids. This good to use after you have optimized the Full Database when selecting a location. Notes: 1. When adding channels from the Full Database, only channels that are inside the set location range, and from the selected Service Types are added to the new list.

When adding channels from a Favorites List that has 'Use Location Control' set to Off , only channels that are from the selected service types are added to the new list. Rename This allows to you rename the Favorites List. Delete This will delete the Favorites List. Information This will show you the file size and number of Systems in the list. Programming Systems.

Any system type that includes the word "Motorola" should be programmed as a Motorola system, even if it uses some or all digital channels.

Edit Name. Edit Sys Options See below. Edit Site See Programming Sites. Edit Department See Programming Departments. Edit Unit IDs Disp. Set Alert Tone. Alert or Off. Set Level. Level or Auto the master volume level. Set Alert Light. Set Color. Set Pattern. On, Slow Blink, or Fast Blink. Delete Unit ID. See Data Naming to name the new system. Delete System. Note: Not all options will appear for all types of systems. Set System Quick Key. Priority ID Scan. Clear All ID Avoids. Set System Number Tag.

Set Audio AGC. Set Avoid. Set Hold Time. Digital Waiting Time Conventional only. ID Search. Review ID Avoids. Digital Threshold Mode Conventional only. Digital Threshold Level Conventional only. Set Avoid This determines whether a System will be scanned or not even if the system is enabled. Temporary Avoids cancel when you cycle power. The default setting is Stop Avoiding. See also Avoiding Transmissions.

Set Hold Time This sets in seconds the amount of time the scanner will scan the System before moving on to the next system. All Unavoided channels will be scanned at least once regardless of this setting. The scanner moves to the next system after the hold time expires, any current transmission ends, and the channel delay time expires.

The default and recommended setting is 0 seconds. Enter the hold time sec. You must program a system fleet map in order for the scanner to properly track and display talk group IDs. Defaults to 0 for all blocks Motorola Type II system. The next available block is prompted to select the next size code Repeat for each block as needed Note: If you select size code 12, 13, or 14, these restrictions apply:.

Since these size codes require multiple blocks, you will be prompted for the next available block. Example: If you assign Block 0 as 12, the scanner prompts you for block 2, the next block available, instead of block 1. See also Priority Scanning. The default setting is Ignore. Yes - the scanner treats all received IDs as unique IDs. Ignore - the scanner rounds all IDs down to the next interval of Analog - The scanner recognizes only analog end transmission codes.

Ignore - The scanner waits for the carrier to drop before leaving a channel. Nothing Avoided appears if nothing is Avoided. The default settings are Off. The default setting is Search.

Search - The scanner opens squelch for any digital signal and displays the NAC being used. Digital Waiting Time Conventional only This setting gives the scanner time to determine if channels on Conventional Systems have digital or analog transmissions.

During this time, the scanner will evaluate the received signal and, if it detects digital data, will open squelch immediately. If digital is not detected before the delay expires, the scanner will open squelch at the end of this delay. This is to prevent "false decode" problems. This setting only affects conventional channels with an Audio Type set to All. The default setting is ms. Note: Any analog transmissions will lose the first part of the transmission up to the wait time you set here. The default setting is Auto.

Auto - Automatically sets the decode threshold based on received signal. Default - Sets the scanner to the default threshold of 8, Auto. If the signal is too low, RX reliability is not high enough to make P25 adjustments correctly [ 1 ]. The default setting is 8. Programming Departments. Set Department Quick Key. Delete Department. Edit Channel. New Department. Set Location Information. Tip: add QK number to name.

See Channel Options. You can program a circle with a radial range or multiple rectangles as a location. Set Latitude. Enter the latitude.

Set Longitude. Enter the longitude. Set Range See also Understanding Range. New Rectangle. Latitude -Top Left. Longitude -Top Left. Latitude - Right Bottom. Longitude - Right Bottom. Stored Rectangle. Edit Rectangle See New Rectangle above. Delete Rectangle. Set Avoid This determines whether a Department will be scanned or not.

New Department See New Department. Programming Sites. Note: Not all options will appear for all sites. Digital Threshold Mode. Set Site Quick Key. Set Attenuator. Digital Threshold Level. Delete Site. New Site. Set Frequencies. Digital Waiting Time. The default setting is Wide. Wide or Narrow. P25 Systems. Explicit mode systems which comprise most systems in use include all information needed to determine voice frequencies on the control channel, leave all entries blank.

The system will automatically detect the band plan and fill in the entries. Implicit systems need you to supply the systems band plan for the scanner to correctly determine voice frequencies. Press Menu to return and repeat for each band plan as needed. The scanner will use the regular Motorola band plan.

These systems require a Custom band plan. Custom band plans require that you enter both a lower and an upper base frequency value. The l ower base frequency or base is always the base frequency as provided in the Radio Reference Database. Use this Excel spreadsheet to calculate the upper base frequency value. If you don't have Excel you can download and install a viewer here.

The upper base frequency can also be found using the Band Plan Calculator at the online Wiki. Band Plan. Select Plan as needed for each Band Plan. Set Base Freq. Set Offset. Set Frequencies This is where you program trunking frequencies for the Site. See also LCN Finder. Defaults to Search. Delete Frequency. See also Site Modulation. Set Attenuator This setting controls whether the scanner attenuates signals on the Site by about 20dBs.

See also Attenuation. Set Avoid This determines whether a Site will be scanned or not. Temp orary Avoids cancel when you cycle power. Digital Waiting Time Motorola Only This setting gives the scanner time to determine if channels on mixed Motorola Systems have digital or analog transmissions.

This setting only affects channels with an Audio Type set to All. Note: Any analog transmissions will lose the first part of the transmission, up to the wait time you set here. Delete Site At Confirm Delete? New Site See New Site. In Scan Mode press Channel to hold on any channel. See also Edit Frequency or ID. At Quick frequency save?

The scanner will save the ID in a Department called Quick Save Department with no quick key assigned in the current system. Note: Not all options will appear for all channels. Set Delay Time. Set Priority. Set Channel Number Tag. You can also Avoid wildcard and partial IDs. Select Any for either or slot 1 or 2. If you are sure the channel is analog, set the channel to Analog Only. All - The scanner determines whether the audio is analog or digital. Digital Only - The scanner will receive the channel only if it is carrying digital audio.

Digital Code Option Conventional only. Search - the scanner searches and displays any digital code received. Analog Only - The scanner will only receive analog audio. Scroll to the desired DCS code you want present with the signal.

Set Modulation Conventional only This setting selects the modulation used for the channel. See also Channel Modulation. Set Attenuator Conventional only This setting controls whether the scanner attenuates signals on the Channel by about 20dB. Default is Custom 1. Set Delay Time This sets in seconds the amount of time the scanner stays on a channel after the transmission has ended before moving to the next channel.

A negative delay will force a resume after that number of seconds. The default setting is 2 seconds. Set Priority This sets the channel as a priority channel while scanning.

Set Alert This setting controls when and how the scanner alerts you if the channel becomes active. Set Avoid This determines whether a channel will be scanned or not. S ee also Channel Volume Offset. Delete Channel At Confirm Delete? New Channel See New Channel. Set Scan Selection. You must first enable each list here, before you can enable the quick key for the list or you will see 'Nothing to Scan' in the display.

Note: You will also need to set a location to enable the Full Database. The other way is using the number keys on the keypad.

See also Selecting Quick Keys. Favorites Quick Key. Press Menu to return. System Quick Key. Favorites List. Manage Full Database. I nformation This will show the database version in the scanner.

Using Startup Keys. You can program each of your Favorites Lists with a Startup Key so that when you power up the scanner and press the key number, just those Favorites List s assigned to the key will be enabled for scan. Turn the scanner off. Press and hold the number key that corresponds to the startup key when you turn the scanner on.

Continue holding the number key until the scanner display shows the number of the startup key configuration. The scanner then checks all Favorites Lists and:. Note : You can't cancel Startup Configuration, i. Priority Scanning. Conventional Priority Scan When the scanner is scanning a Conventional System, it interrupts scanning, based on the Priority Interval and Max Channels settings, to check priority channels for activity.

The more channels you have set to priority, the longer the interruption will be. The Favorites List s and System s containing the priority channel s have to be enabled and not Avoided or the scanner will display Priority Scan No Channel.

Conventional Priority DND The scanner checks priority channels, based on the Priority Interval and Max Channels settings, only when not receiving other conventional channels so there is no interruption in scanning with conventional systems. Priority ID Scan This function is similar to conventional priority although there is no interruption during the transmission. Priority ID Scan is always on for a system if enabled in the system setting.

Priority is checked in between transmissions, when the scanner is receiving the control channel, and during the channel delay period. The scanner can only look for priority IDs in the trunked system it is currently scanning.

Preemptive Priority ID Scanning For Motorola systems that have channel priority active on the system, if you flag a channel as priority and the system also has that TGID identified as a priority channel, the scanner will preempt any current transmission if the TGID becomes active. The highest priority is for channels in System QK 0. The lowest priority is for channels in System QK Priority for channels in the same Department follows the order in which they were created.

Priority Options. Set Priority Sets the Priority Mode. You can also toggle these modes in Scan Mode by pressing Func then. Off - The Priority feature is off. Priority DND - The scanner checks conventional priority channels only when not receiving other conventional channels. PRI appears in the display reversed -. Priority Scan - The scanner checks conventional priority channels. PRI appears in the display. Set Interval This sets in seconds how often the scanner will check the priority channels.

If there are more priority channels than the value you select, the channels are divided into more than one group and the scanner scans each group in turn. Example: If you set the maximum channels to 20 and there are priority channels, the scanner checks those channels in groups of 20 and takes a total of 5 intervals to complete the priority scan.

Scanning Order. With previous scanners, you selected banks to scan. See also Understanding Quick Keys. The scanner will not scan all Systems in one Favorites List and then move to the next List. Systems, Departments, and Sites with the same QK are scanned in order of creation. Conventional Channels in Departments are also scanned in order of creation.

The Database is scanned next, in order of creation. The scanner scans a system for the duration you set using the System Hold Time option. For trunked systems, the scanner moves to the next system after the hold time expires, the current transmission ends, and the channel delay expires.

Conventional systems operate similarly, but all Unavoided channels are scanned at least one time regardless of the hold time setting. IDs are not really scanned. The scanner checks for any activity in the trunking system and:. Contents Scanning Checklist: 1. Service Types for the channels you want to monitor must be set to On. Check or uncheck 'Monitor Full Database'.

Custom 1 is needed for miscellaneous channels. Scan Receive. Scan Mode. Number Tag. Search with Scan, Frequency Hold. Site Hold. Notes: You can press Menu or Avoid to cancel any entry. If you make a mistake entering numbers, you can use the scroll control to backup and correct entries. Example: 3. Example: 0. FLQK 3 current. System QK 3 current. SQKs are not assigned. D is first digit of Site QK.

Blinking number on the right is second digit of Site QK. System QK for the Site is shown above. Site QK 52 current. Site QKs are Off. Site QKs are not assigned.

System QK for the Department is shown above. Press Avoid to exit the QK Navigation screen, or. Leading 0's required to view complete status. Scan Menu Contents. FLQKs - Press 0. FLQKs - Press 1. Toggle Display Modes.

Note: ID Search is not available with the Database. You can set how long a period Replay records from 30 seconds to seconds 4 minutes. While you can replay those recordings immediately and continue replaying them, you cannot save them for future listening. See also Replay Options. While scanning, press Replay.

Turn the Scroll Control to select recordings. Note: Replay is not available when recording is enabled. These recording sessions are saved and can be replayed on demand. While scanning, press Func then Replay. Resets to Off when you turn off the scanner. Review Recordings. While scanning, press and hold Replay. Scan Hold.

P ress Channel to hold on a Channel. You can now scroll all Channels. Press Channel to release Channel Hold. Press Dept to pause for 2 seconds then hold on any Department. Department is reversed in the display for Pause Mode Double press Dept to hold without a pause. Press Dept then quickly scroll to any Department in Pause Mode.

Double press Dept to release Department Hold. Press System to pause for 2 seconds then hold on any System. System is reversed in the display for Pause Mode Double press System to hold without a pause. Press System then quickly scroll to any System in Pause Mode. Double press System to release System Hold.

Press Func then Site to hold on any Site in the current System. To Permanent Avoid press Avoid twice quickly. To Permanent Avoid press Dept then quickly press Avoid twice. To Permanent Avoid press System then quickly press Avoid twice.

Press Func then Site to release Site Hold. Store a Channel from the Full Database. Add to Favorites List. At Are you sure? New Department Then see Data Naming. After storing the ID, you will be at the Channel Options menu to complete the settings for the new channel. Store a Search Frequency Search with Scan. Then see Storing Search Frequencies. Channel Attenuation - Press Channel to hold on the channel.

Press Func then 4 ATT to toggle attenuation. Global Attenuation - Press Channel to hold on any channel. Press Func then press and hold 4 ATT to toggle global attenuation. ATT blinks in the display when global attenuation is on. Press Channel to hold on any Channel.

Press Channel to release Channel hold. Press Channel to hold on the channel. Press Func then 7 IFX to toggle on or off. View Repeater Frequency for a Conventional Channel. Press Func then press and hold 8 REV. Channel Volume Offset. Scan Priority Modes. Range Control — Lets you set how far out from your current location the scanner will search for channels in Favorites Lists and the database.

Location precision for departments and sites that allows you to define a location and range using rectangles instead just of a single circle. Control Channel Only Scanning — With Motorola trunking frequencies, you do not have to program voice channel frequencies. Instant Replay — Plays back up to seconds 4 minutes of the most recent transmissions. Audio Recording — Capture transmissions for later playback. For each alert in the scanner, you can select from 9 different tone patterns, 15 volume settings, 7 colors, and 3 flash patterns.

Trunking Discovery — Monitors system traffic on a trunked radio system to find unknown IDs and automatically records audio from and logs new channels for later review and identification. Conventional Discovery — Searches a range of frequencies to find unknown frequencies and automatically records audio from and logs new channels for later review and identification. Fire, Police, Railroad, etc. Scan Speed - 85 channels per second. Multi-Level Display and Keypad light — Makes the display and keypad easy to see in dim light with three light levels.

Start-up Configuration — You can program each of your Favorites Lists with a Startup Key so that when you power up the scanner and press the key number, just those Favorites Lists assigned to the key will be enabled for scan. Close Call Do-not-Disturb checks for Close Call activity in between channel reception so active channels are not interrupted.

Broadcast Screen — Allows the scanner to ignore hits on known broadcast frequencies including pager frequencies in search and Close Call modes. You can also program up to 10 custom frequency ranges that the scanner will ignore. You can set up to 32 Tone-Outs. The scanner will also search and display unknown tones. Status Not open for further replies.

I'm trying to find something that gives ideas on using the quick key. I understnd you can leave it blank and it will be enabled, and you can set them up to bu used by the tags.

I'm just having a problem grasping how you can use the system keys, department keys to organize them. Any assistants will be gratly appreciated. I vaven't found any youtube videos that goes over that and also the manual and Easier to read hasn;'t helped either. Joined Apr 24, Messages Location Upstate.

Joined May 2, Messages 3 Location Maine. After a very long time, I am still trying to grasp the culture and logic of the use of quick keys and tags. I now get it that I can turn on or off the scanning of a service with a QK as long as the service is switched on initially in the scanner.

It took me a while to figure that one out..



0コメント

  • 1000 / 1000